Article Document Academic Article Information Content Entity Continuant Continuant Journal Article Entity Entity Generically Dependent Continuant 2025-05-06T10:45:12 RDF description of Normalization of left ventricular ejection fraction and incidence of appropriate antitachycardia therapy in patients with implantable cardioverter defibrillator for primary prevention of sudden death - http://repository.healthpartners.com/individual/document-rn41 <p>BACKGROUND: Patients with severely depressed left ventricular ejection fractions (LVEFs) receive implantable cardioverter-defibrillators (ICDs) for the primary prevention of sudden death. In some patients, however, LVEF may improve or even normalize over time. Limited data are available on the incidence of appropriate antitachycardia therapy, including pacing and shock, in these patients. METHODS AND RESULTS: We retrospectively identified consecutive patients at our institution with an ICD for primary prevention who had LVEF measurement available at initial implantation and at the time of generator replacement. None of these patients had ever received appropriate antitachycardia therapy before generator replacement. The incidence of appropriate antitachycardia therapy after generator replacement was assessed. Of the 125 patients who received generator replacement, 53 (42%) received an ICD and 72 (58%) a cardiac resynchronization therapy-defibrillator (CRT-D). Among them, 30 (21%) had LVEF normalized to >/=50%, 25 (17%) had LVEF partially improved to 36%-49%, and 70 (63%) had LVEF that remained depressed at </=35%. During an overall follow-up period of 25 +/- 18 months, none of the individuals with normalized LVEF experienced appropriate antitachycardia therapy regardless of ICD or CRT-D. Meanwhile, 20% of patients with LVEF at 36%-49% and 14% of patients with LVEF at </=35% received appropriate ICD therapy. The omnibus P value for any differences among the 3 LVEF groups was 0.046 for the entire cohort, 0.01 for ICD, and 0.15 for CRT-D patients. CONCLUSIONS: These preliminary data suggest that patients with reduced LVEF and primary-prevention ICDs who normalize their LVEF over time may be at lower risk of appropriate antitachycardia therapy.<p> 10.1016/j.cardfail.2015.10.015 Mortality 2 Stroke Retrospective Studies Normalization of left ventricular ejection fraction and incidence of appropriate antitachycardia therapy in patients with implantable cardioverter defibrillator for primary prevention of sudden death Journal of Cardiac Failure public Prevention document-rn41 22 Surgery Follow-Up Studies 2022-02-21T22:48:57.408-06:00 Cardiovascular Diseases 24182 Heart Diseases 14801