Article Document Academic Article Information Content Entity Journal Article Continuant Continuant Entity Entity Generically Dependent Continuant 2025-05-06T18:15:18 RDF description of Diagnostic performance of high sensitivity compared with contemporary cardiac troponin I for the diagnosis of acute myocardial infarction - http://repository.healthpartners.com/individual/document-rn2658 Sensitivity and Specificity public Drugs and Drug Therapy Heart Diseases 10.1373/clinchem.2017.272930 Biomarkers Diagnostic performance of high sensitivity compared with contemporary cardiac troponin I for the diagnosis of acute myocardial infarction 63 Emergency Medicine 14392 2022-02-21T22:48:57.408-06:00 Clinical Trials Myocardial Infarction document-rn2658 10 Clinical Chemistry 23364 <p>BACKGROUND: We examined the diagnostic performance of high-sensitivity cardiac troponin I (hs-cTnI) vs contemporary cTnI with use of the 99th percentile alone and with a normal electrocardiogram (ECG) to rule out acute myocardial infarction (MI) and serial changes (deltas) to rule in MI. METHODS: We included consecutive patients presenting to a US emergency department with serial cTnI onclinical indication. Diagnostic performance for acute MI, including MI subtypes, and 30-day outcomes were examined. RESULTS: Among 1631 patients, MI was diagnosed in 12.9% using the contemporary cTnI assay and in 10.4% using the hs-cTnI assay. For ruling out MI, contemporary cTnI </=99th percentile at 0, 3, and 6 h and a normal ECG had a negative predictive value (NPV) of 99.5% (95% CI, 98.6-100) and a sensitivity of 99.1% (95% CI, 97.4-100) for diagnostic and safety outcomes. Serial hs-cTnI measurements </=99th percentile at 0 and 3 h and a normal ECG had an NPV and sensitivity of 100% (95% CI, 100-100) for diagnostic and safety outcomes. For ruling in MI, contemporary cTnI measurements had specificities of 84.4% (95% CI, 82.5-86.3) at presentation and 78.7% (95% CI, 75.4-82.0) with serial testing at 0, 3, and 6 h, improving to 89.2% (95% CI, 87.1-91.3) by using serial cTnI changes (delta, 0 and 6 h) >150%. hs-cTnI had specificities of 86.9% (95% CI, 85.1-88.6) at presentation and 85.7% (95% CI, 83.5-87.9) with serial testing at 0 and 3 h, improving to 89.3% (95% CI, 87.3-91.2) using a delta hs-cTnI (0 and 3 h) >5 ng/L. CONCLUSIONS: hs-cTnI and contemporary cTnI assays are excellent in ruling out MI following recommendations predicated on serial testing and the 99th percentile with a normal ECG. For ruling in MI, deltas improve the specificity. ClinicalTrials.gov Identifier: NCT02060760.<p>